Made in Germany

High Pressure Cleaner KSM Series

Stationary multiple outlet units, designed for continuous professional use.

Models

Standard Equipment

  • 7" touch screen monitor
  • PLC controls Siemens S7-1200
  • Automatic switch On/Off control for high pressure pumps
  • Automatic stand-by operation
  • Pressureless pipes in stand-by
  • Booster supply pump
  • 60 l water storage tank
  • Water supply separation acc. water reg.
  • Maintenance interval display
  • INOX versions: stainless steel (food safe)

Category: High Pressure Cleaners


Model2 Pumps 
KSM1840
3 Pumps 
KSM2740
4 Pumps
KSM3640
5 Pumps 
KSM4540
6 Pumps
KSM5440
Order N°1561
156101 (INOX)
1562
156201 (INOX)
1563
156300 (INOX)
1564
156400 (INOX)
1565
156500 (INOX)
Voltage3/ 400-415 V/ 50 Hz3/ 400-415 V/ 50 Hz3/ 400-415 V/ 50 Hz3/ 400-415 V/ 50 Hz3/ 400-415 V/ 50 Hz
Operating pressure30-180 bar / 3-18 MPa30-180 bar / 3-18 MPa30-180 bar / 3-18 MPa30-180 bar / 3-18 MPa30-180 bar / 3-18 MPa
Max. Pressure200 bar / 20 MPa200 bar / 20 MPa200 bar / 20 MPa200 bar / 20 MPa200 bar / 20 MPa
Water Output900-1800 l/h900-2700 l/h900-3600 l/h900-4500 l/h900-5400 l/h
Nozzle size2 x 0503 x 0504 x 0505 x 0506 x 050
Max. inlet temperature80 °C80 °C80 °C80 °C80 °C
Pump speed1400 rpm1400 rpm1400 rpm1400 rpm1400 rpm
Connected load14.0 kW / 25.5 A21.0 kW / 38 A27.0 kW / 50 A33.5 kW / 60.5 A40.0 kW / 72.5 A
Electrical protection3 x 32 A slow-blowing3 x 50 A slow-blowing3 x 63 A slow-blowing3 x 80 A slow-blowing3 x 80 A slow-blowing
Weight net493 kg
Dimensions (L x W x H)1130 x 800 x 2090 mm1130 x 800 x 2090 mm2130 x 800 x 2090 mm2130 x 800 x 2090 mm2130 x 800 x 2090 mm
  • Self-supporting, robust, device chassis made from galvanized steel and powder-coated (Option INOX: device chassis made out of stainless steel), suitable for floor installation
  • Triplex-Piston pump with chrome-nickel pump head, hot water-resistant up to 85°c, high-performance ceramic piston, stainless-steel valves
  • Leakage return
  • Booster pump for charging the high pressure pumps (cavitation avoidance)
  • Automatic pump-on and shut-off control by PLC
  • Total-Switch-off between 5 and 600 min – adjustable, with leakage recognition
  • Unloader safety valve for monitoring
  • Pressureless pipe system in standby mode
  • Robust rotary ON/OFF switch